适合在发电厂使用耐硅胶护套可以抗热,抗化学腐蚀,耐油和耐酸

详细介绍

SiHF-C-Si- 屏蔽硅橡胶电缆结构:镀锡铜 DIN VDE 0295 c5,BS 6360 c.5.EC 60228 c1.5砗橡胶绝缘,导体色标参照 DIN VDE 0293-308,单色,或具有白色连续教字的黑色道题,两芯导体:棕色/蓝色, 绕包, 黄绿接地线(三苾)砗胶内护套 镀锡铜丝编织,夏盖率约 85% 砗橡胺绝缘外护套 护套颜色适宜红棕色。技术参数:具有较高的耐热范围的特殊硅胶单导体电缆适应于DIN VDE 0250 part 1和part 816

工作温度:-60°℃~ +180°℃瞬间可达到的温度:+2200℃,导体的工作温度:+180。额定电压:300/500V,测试电压: 2000 V,绝缘阴抗,200 MQxkm,弯曲半径: 柔软10x外径,固定安装5x外径,阻抗:不大于250Q/km,辐射阻抗:达 20x106 cJ/kg(可达20Mrad)产品性能:

耐高油分子,防动植物油,酒精,增塑剂和稀释酸,碱液和盐溶解,氧化物质,热带气候的影响,湖泊水,氧气无卤,参考DIN VDE 0482 part 267/EN 50267-2-1/IEC60754-1(等同于DIN VDE 0472 part815)耐火性能:不蔓延

测试参考 DIN VDE 0482 part 265-2-1/EN 50265-2-1/EC60332-1(等同于DIN VDE 0472 part804 测试方法 B)固定安装在露天或通风管系统以及管道中。否则,硅橡胶的机械性能在超过90度的封闭空气中会减弱。



Suitable for use in power plants silicone resistant sheath can resist heat, chemical corrosion, oil and acid

Detailed introduction

Sihf-c-si-shielded silicone rubber cable construction: tinned copper DIN VDE 0295-C5,BS 6360 c.5.EC 60228 c1.5 Tridacnide insulation, conductor color code reference DIN VDE 0293-308, monochrome, or black with white continuous text, Two conductors: brown/blue, wrapped, yellow-green grounding wire (three bibi) Tridacnidacnamine inner sheath tinned copper wire braided, summer cover rate about 85% Tridacnamine insulation outer sheath sheath color suitable for reddish-brown. Specifications: Special silicone single conductor cables with a high heat resistance range for DIN VDE 0250 part 1 and part 816

Operating temperature :-60° C ~ +180° C Instant attainable temperature :+2200 ° C, conductor operating temperature :+180. Rated voltage :300/500V, test voltage: 2000 V, insulated negative resistance,200 MQxkm, bending radius: soft 10x outer diameter, fixed installation 5x outer diameter, impedance: not more than 250Q/km, radiation impedance: up to 20x106 cJ/kg(up to 20Mrad)

Resistance to high oil molecules, resistance to animal and plant oils, alcohol, plasticizers and diluted acids, lye and salt dissolves, oxidizing substances, effects of tropical climate, lake water, oxygen halogen-free, Reference DIN VDE 0482 part 267/EN 50267-2-1/IEC60754-1(e to DIN VDE 0472 Part 815) Fire resistance: non-spreading

Test reference DIN VDE 0482 part 265-2-1/EN 50265-2-1/EC60332-1(e to DIN VDE 0472 Part 804 test method B) Fixed installation in open air or ventilation duct systems and ducts. Otherwise, the mechanical properties of silicone rubber will be weakened in the enclosed air of more than 90 degrees.